Flow Cytometer


 

  

Features:

 

High Resolution

Quality components, reliable optical andfluidic designs and innovative algorithm realize excellent fluorescenceresolution and minimum variation.

 

High Sensitivity

Higher sensitivity enhances the capability todiscern weak positive signal.

Broad Dynamic Range

218 range of fluorescent or scattered lightsignals.

Low Carryover

Effective sample needle wash mechanism andtime sequence design reduce the carryover contamination to 0.5%.

Data Generation &Filtering

Innovative signal extraction and effectivedenoise filter algorithm.

Reliable Optics

The immobilized optic design greatly simplifythe maintenance and calibration of the instrument. The effective locking mechanismeliminates most undesired vibration and thus diminishes fluctuationaccordingly. The low power consumption solid phase laser can provide moreuniform focal spot. The TEC temperature controller is integrated into the laserto modulate the energy fluctuation and spot drifting caused by heat, and extendthe laser life expectancy. The whole optic module is free of daily alignmentand maintenance for the sake of operational convenience and data consistency.

Absolute Cell Counting

Precision syringe volume control devoid ofcounting tube or other reagents. Immune to computational error from minorpressure change or volume measurement deviation.

Auto Gain

Automatic PMT gain adjustment,precisionoffluorescence compensation down to 0.01% in areal time manner.

Automatic Sample Load

Automatic Sample Loader in the standardconfiguration can hold 32 samples with precursive mixing against precipitationto break the throughput bottle neck.

Versatile Software

Application software for data collection,analysis and report; process-oriented intuitive user interface in modulardesign; quick switch between multi- language pack; direct PDF reportgeneration; broad spectrum for gate drawing methods on scatterplots.

 

Specifications:

Feature

Performance

Resolution

FSC≤2.0%; FITC,PE≤2.0%; PerCP,PE-Cy7,APC,APC-Cy7≤4.0%

Fluorescence Sensitivity

FITC≤120 MESF, PE≤80 MESF

Dynamic Range

1.6×107

Contamination Carrying Rate

≤0.1%

Maximum Analysis Speed

50,000 Events/s

Min. Specimen Volume

100μL(test tube: φ12×75 mm)

Max. Particle Size

40μm

Absolute Count

Absolute Volume Method

Flow Rate

12μL/min, 33μL/min, 82μL/min, 124μL/min, 4 levels flow

Sample Capacity

32

 

 

 

 

Laser

Filter

Fluorescein

FC1030

FC2040

FC2050

FC2060

Blue, 488 nm Solid 43mW

FL1 (530/30)

FITC

FL2 (585/40)

PE

FL3 (670LP)

PerCP

FL5(785/60)

PE-CY7

 

 

Red, 638 nm Solid 55mW

FL4 (660/20)

APC

 

FL6 (785/60)

APC-CY7

 

 

 

 

 